Testing Ignition unit You pay this amount if your unit has been tested by Carmo. Testing within 3 working days. (We also offer a fast service, with delivery by 10:00, ready after 16:00 Mon-Fri)
Test procedure: Our tests are Simulation-based tests, all signals that are offered to the unit are simulated on our unique test table. This way we can approach the reality close to 100%. We test dynamic, not static measures such as using tables from the workshop manual. What is tested?: - Variable load on outputs - Advance ignition curve relative to the rpm - Power of the spark at variable load - Charging of the ignitioncoil in TCI systems and peak voltage at CDI Systems - Operation at different voltages (8V - 15.5 V) - Temperature dependence - Idle up to the rpm limiter - Endurance test, at least 25 minutes (longer on request) - Vibration - Water resistance - Electromagnetic compatibility tests - If present, tachometer output, Electronic fuel pump output, TPS and vacuum input, standard / neutral safety If possible, the circuit board will be provided with two layers of professional moisture protective coating after testing.